Sign In | Join Free | My burrillandco.com
Home > Compression load cell >

Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN

    Buy cheap Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN from wholesalers
     
    Buy cheap Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN from wholesalers
    • Buy cheap Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN from wholesalers
    • Buy cheap Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN from wholesalers
    • Buy cheap Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN from wholesalers
    • Buy cheap Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN from wholesalers

    Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN

    Ask Lasest Price
    Brand Name : Forsentek
    Model Number : FCL
    Certification : CE
    Payment Terms : T/T,Western Union or Paypal
    Supply Ability : 2800pcs/month
    Delivery Time : 3~25 working days
    • Product Details
    • Company Profile

    Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN

    Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN

    Rod End Load Cell Force Sensor FCL is made of stainless steel based on strain gauge technology offering 100N / 200N / 300N / 500N / 1kN / 2kN / 3kN / 5kN / 10kN / 20kN / 30kN / 50kN rated capacities intended for both tension and compression force measurement. The threaded rod on the top of the sensor can be used to mount attachments such as load buttons and eye bolts for different applications. Compared to universal side cable outlet, force transducer FCL adopts bottom cable outlet which helps save the mounting space, tension compression load cell FCL is suitable for in-line force measurement. Model FCL can be modified or customized as per request of clients or different applications.
    rod_end_load_cell_100N_200N_500N_1kN_2kN_5kN
    Dimensions(Unit in milimeter)
    rod_end_compression_force_transducer_100N_200N_300N_500n_1kN
    Specifications

    Capacity

    10kg / 100N / 22lb
    20kg / 200N / 44 lb
    30kg / 300N / 66lbf
    50kg / 500N / 110lb
    100kg / 1kN / 220 lb
    200kg / 2kN / 440lb
    300kg / 3kN / 660 lb
    500kg / 5kN / 1100lb
    1000kg / 10kN / 2.2k lb
    2000kg / 20kN / 4.4 klb
    3000kg / 30kN / 6.6klb
    5000kg / 50kN / 11 klb

    Rated output1.5mV/V
    Excitation3-15V
    Zero balance±0.05mV/V
    Nonlinearity±0.3% R.O.
    Hysteresis±0.3% R.O.
    Nonrepeatability±0.1% R.O.
    Creep(5min)±0.1% R.O.
    Safe overload150% F.S.
    Ultimate overload200% F.S.
    Compensated temperature0...+40oC
    Operating temperature-20...+60oC
    Temperature shift zero±0.03% R.O./oC
    Temperature shift span±0.03% R.O./oC
    Input resistance380±30 ohms
    Output resistance350±10 ohms
    Insulation resistance>5000M ohms
    Ingress protectionIP65
    Material of elementStainless steel
    CableØ3*2000mm 4-core shielded cable

    Wiring code

    Red--Excitation+ Black--Excitation-

    Green--Signal+ White--Signal-


    A Force Sensor is a transducer that converts mechanical load into mV signal proportional to the applied force.The acting force causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally,thus the load/force can be measured by measuring the output signal from the transducer.

    Load cell output: = (Power supply * Rated output) * Load / Capacity
    Rated output is normally within 1mV/V~3mV/V.
    Power supply is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
    Example one: FCL-300N with 1.5mV/V rated output powered by 3.3V DC,the output range is -4.95mV...+4.95mV(Tension and compression).
    Example two: FCL-100N with 1.5mV/V rated output powered by 10V DC,the output range is -15mV...+15mV(Tension and compression).

    A signal conditioner is normally used with the load cell to deliver -5~5V, 0-10V or 4-20mA output for easy data processing:

    Example: FCL-500N working with -5-5V amplifier,the load-output relationship will be 0-500N compression load VS 0-5V output,0-500N tension load VS 0-(-5V) output,when you get 2V output,it means the current load is 200N compression force,when you get -1V output,it means the current load is 100N tension force,and so on.
    Rod End Compression Load Cell Force Sensor For Tension And Compression Force Measurement
    rod end force transducer 5kN 3kN 2KN 1KN 500N 200N 100N

    Click here to download datasheet






















    Quality Rod End Compression Load Cell Force Sensor 100N 200N 500N 1kN 2kN 3kN 5kN 10kN for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Forsentek Co., Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)