Sign In | Join Free | My burrillandco.com
Home > Load button load cell >

Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor

    Buy cheap Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor from wholesalers
     
    Buy cheap Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor from wholesalers
    • Buy cheap Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor from wholesalers
    • Buy cheap Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor from wholesalers
    • Buy cheap Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor from wholesalers
    • Buy cheap Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor from wholesalers

    Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor

    Ask Lasest Price
    Brand Name : Forsentek
    Model Number : FC8E
    Certification : CE
    Payment Terms : T/T,Western Union or Paypal
    Supply Ability : 2675pcs/month
    Delivery Time : 3~20 working days
    • Product Details
    • Company Profile

    Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor

    Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor

    Smallest Compression Load Cell FC8E is made of stainless steel based on metal foil stain gauge technology intended for compression force measurement. 1000 ohms high resistance strain gauge delivers better stability compared to commonly used 350ohms gauges, miniature load cell FC8E offers 0-50N / 0-100N / 0-200N / 0-500N four measuring ranges to choose from. Smallest button load cell FC8E is featured with only 8mm outer diameter and 6mm total height which makes it extremely suitable for force measurement applications with limited mounting space.Typical applications for transducer FC8E are such as clamping force measuremen,force overload protection,load distribution analysis,pressing die force measurement,auto equipment,assembly line and so on.
    smallest compression load cell 5kg 10kg 20kg 50kg
    Dimensions(unit in milimeter)
    smallest force sensor 50N 100N 200N 500N
    Specifications

    Capacity

    50N / 5kg / 11lb

    100N / 10kg / 22lb

    200N / 20kg / 44lb

    500N / 50kg / 110lb

    Rated output1.0 mV/V
    Excitation3-8V
    Zero balance±0.1mV/V
    Nonlinearity±1% R.O.
    Hysteresis±1% R.O.
    Nonrepeatability±0.5% R.O.
    Creep(3min)±0.5% R.O.
    Safe overload150% F.S.
    Ultimate overload200% F.S.
    Compensated temperature-10...+40oC
    Operating temperature-20...+60oC
    Temperature shift zero±0.05% R.O./oC
    Temperature shift span±0.05% R.O./oC
    Input resistance900±100 ohms
    Output resistance900±100 ohms
    Insulation resistance>2000M ohms
    Ingress protectionIP64
    Material of elementStainless steel
    CableØ2*4000mm 4-core shielded
    Wiring code

    Red--Excitation+ Black--Excitation-

    Green--Signal+ White--Signal-


    Load cell glossary:

    Load Cell:A device which produces an output signal proportional to the applied weight or force.

    Wheatstone Bridge:A Wheatstone bridge is a network of four resistive legs. One or more of these legs can be active sensing elements. The Wheatstone bridge is the electrical equivalent of two parallel voltage divider circuits. R1 and R2 compose one voltage divider circuit, and R4 and R3 compose the second voltage divider circuit. The output of a Wheatstone bridge is measured between the middle nodes of the two voltage dividers.
    Excitation: The voltage applied to the input terminals of the load cell.

    Rated Capacity: The maximum axial load the load cell is designed to measure within its specifications.

    Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.

    Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.

    Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.

    Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

    Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

    Ultimate Overload: The maximum load in percent of rated capacity which can be applied without producing a structural failure.

    Operating Temperature: The extremes of temperature within which a load cell will operate without permanent adverse change to any of its performance characteristics.

    Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.

    Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.

    Input Resistance: The resistance of the load cell bridge circuit measured at the positive and negative excitation terminals with no load applied and with the output terminals open-circuited.

    Output Resistance: The resistance of the transducer bridge circuit measured at the positive and negative signal terminals with no load applied and with the input terminals open-circuited.

    The output signal of load sensor FC8E is normally within 0...+10mV. A signal conditioner can be used to convert mV signal into 0-5V / 0-10V / 4-20mA output, taking Smallest Load Cell FC8E-100N working with amplifier FSC(0-10V)-24V for example, the force-voltage relationship will be 0-100N load VS 0-10V voltage, 1V corresponds to 10N load, 2V voltage corresponds to 20N force,and so on.

    Smallest Compression Load Cell 50N 100N 200N 500N Smallest Compression Force Transducer
    smallest button load cell 5kg 10kg 20kg 50kg

    Click here to download datasheet

    Quality Smallest Button Load Cell 50N 100N 200N 500N Smallest Compression Force Sensor for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Forsentek Co., Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)