Sign In | Join Free | My burrillandco.com
Home > Load button load cell >

Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer

    Buy cheap Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer from wholesalers
     
    Buy cheap Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer from wholesalers
    • Buy cheap Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer from wholesalers
    • Buy cheap Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer from wholesalers
    • Buy cheap Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer from wholesalers
    • Buy cheap Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer from wholesalers

    Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer

    Ask Lasest Price
    Brand Name : Forsentek
    Model Number : FCCK
    Certification : CE
    Payment Terms : T/T,Western Union or Paypal
    Supply Ability : 1975pcs/month
    Delivery Time : 3~20 working days
    • Product Details
    • Company Profile

    Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer

    Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer

    Ultra Thin Miniature Compression Type Button Load Cell Force Sensor FCCK is made of stainless steel based on strain gauge technology, very compact size with 12.7mm outer diameter and 3.95mm height which makes miniature force transducer FCCK suitable for compression force measurement applications with limited mounting space.Smallest Compression Sensor FCCK offers 0-1000N / 0-500N / 0-200N / 0-100N / 0-50N five rated measuring ranges to choose from. Transducer FCCK utilizes 1000 ohms bridge resistance for lower heat emission and better stability, you may find Thin Load Cell FCCK suitable for applications such as clamping force measurement, force overload protection, load distribution measurement, pressing die force measurement, auto equipment, medical divices, assembly line, and so on. Custom made service is available for similar structures with different capacities.

    smallest force sensor 1000n 500n 200n 100n 50n
    Dimensions(unit in "mm")
    smallest compression load cell 100kg 50kg 20kg 10kg 5kg
    Specifications

    Capacity

    50N / 5kg / 11 lb
    100N / 10kg / 22lb
    200N / 20kg / 44 lb
    500N / 50kg / 110 lb
    1000N / 100kg / 220lb

    Rated output1.5mV/V
    Excitation3-12V
    Zero balance±0.1mV/V
    Nonlinearity±2% R.O.
    Hysteresis±2% R.O.
    Nonrepeatability±0.5% R.O.
    Creep(3min)±0.5% R.O.
    Safe overload150% F.S.
    Ultimate overload200% F.S.
    Compensated temperature-10...+40oC
    Operating temperature-20...+60oC
    Temperature shift zero±0.05% R.O./oC
    Temperature shift span±0.05% R.O./oC
    Input resistance1000±100 ohms
    Output resistance1000±100 ohms
    Insulation resistance>2000M ohms
    Ingress protectionIP65
    Material of elementStainless steel
    CableØ1.2*3000mm 4-conductor
    Wiring code

    Red--Excitation+ Black--Excitation-

    Green--Signal+ White--Signal-


    Smallest Compression Force Transducer 1kN 500N 200N 100N 50N Compression Sensor

    smallest force transducer 1000n 500n 200n 100n 50n
    Brief instruction of Rated output(or Sensitivity):
    Definition: The signal produced by load cell(or force transducer) when rated load is applied, expressed in terms of mV/V. The rated output indicates the output signal range of a sensor.
    Sensor output = (Power supply * Rated output) * Load / Capacity
    Rated output is normally within 1mV/V~3mV/V.
    Power supply is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
    Example one: FCCK-50N with 1.5mV/V power by 5V DC,the output range is 0~7.5mV proportional to the applied load.
    Example two: FCCK-100N with 1.6mV/V power by 10V DC,the output range is 0~16mV proportional to the applied load.

    The mV output from the loadcell sometimes cannot be recognized by signal processing units directly,so signal conditioner is introduced to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
    Example: Button Load Cell FCCK-500N working with amplifier FSC(0-5V)-24V,the force-voltage relationship will be 0-500N force VS 0-5V output.

    Click here to download datasheet

    Quality Smallest Compression Force Sensor 1kN 500N 200N 100N 50N Compression Transducer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Forsentek Co., Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)