Sign In | Join Free | My burrillandco.com
Home > Tension compression load cell >

M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell

    Buy cheap M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell from wholesalers
     
    Buy cheap M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell from wholesalers
    • Buy cheap M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell from wholesalers
    • Buy cheap M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell from wholesalers
    • Buy cheap M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell from wholesalers
    • Buy cheap M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell from wholesalers
    • Buy cheap M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell from wholesalers

    M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell

    Ask Lasest Price
    Brand Name : Forsentek
    Model Number : FS4A
    Payment Terms : T/T,Western Union or Paypal
    Supply Ability : 3950pcs/month
    Delivery Time : 3~25 working days
    • Product Details
    • Company Profile

    M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell

    M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell

    Universal S Type Load Cell FS4A is strain gauge based intended for traction and compression force measurement. S Beam Load Cell FS4A offers 0-2kg / 0-5kg / 0-10kg / 0-20kg / 0-30kg / 0-50kg six rated measuring ranges to choose from. M6 metric threaded holes located on both ends can be used to mount attachments such as eye bolts and hooks for adapt to different cases. S type Compression Traction Load Cell FS4A offers an accurate and affordable measuring solution for applications such as material testing machines, hanging scales, hopper weighing, automation equipment, coefficient of friction testing systems, industrial force control/ feedback, push-pull gauges and so on.

    2kg_S-type_load_cell_5kg

    Load cell glossary:

    Wheatstone Bridge:A Wheatstone bridge is a network of four resistive legs. One or more of these legs can be active sensing elements. The Wheatstone bridge is the electrical equivalent of two parallel voltage divider circuits. R1 and R2 compose one voltage divider circuit, and R4 and R3 compose the second voltage divider circuit. The output of a Wheatstone bridge is measured between the middle nodes of the two voltage dividers.
    Excitation: The voltage applied to the input terminals of the load cell.

    Rated Capacity: The maximum axial load the load cell is designed to measure within its specifications.

    Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.

    Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.

    Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.

    Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

    Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

    Ultimate Overload: The maximum load in percent of rated capacity which can be applied without producing a structural failure.

    Operating Temperature: The extremes of temperature within which a load cell will operate without permanent adverse change to any of its performance characteristics.

    10kg_S-type_load_cell_20kg

    Specifications

    Rated Capacity

    2kg / 5kg / 10kg / 20kg / 30kg / 50kg

    20N / 50N / 100N / 200N / 300N / 500N
    4.4lb / 10lb / 20lb / 45lb / 66lb / 110lb

    Rated output2.0mV/V
    Excitation3-15V
    Zero balance±0.05mV/V
    Nonlinearity±0.03% of rated capacity
    Hysteresis±0.02% of rated capacity
    Nonrepeatability±0.02% of rated capacity
    Creep(30min)±0.03% of rated capacity
    Safe overload150% of rated capacity
    Ultimate overload200% of rated capacity
    Compensated temperature-10...+40oC
    Operating temperature-20...+60oC
    Temperature shift zero±0.05% R.O./10oC
    Temperature shift span±0.05% R.O./10oC
    Input resistance400±50 ohms
    Output resistance350±5 ohms
    Insulation resistance>5000M ohms
    Ingress protectionIP65
    Material of elementAluminum alloy
    CableAWG32*500mm 4-wire
    Wiring code

    Red--Excitation+ Black--Excitation-

    Green--Signal+ White--Signal-


    M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell

    50kg_S-type_load_cell_30kg

    Output signal of load cell and amplifier:
    Load cell output: = (Power supply * Rated output) * Load / Capacity
    Rated output of S-Type Load Cell FS4A is normally around 2.0mV/V.
    Power supply of S-Beam Load cell FS4A is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the output range of S Type Tension Compression Load Cell FS4A is normally within -30mV…+30mV for bidirectional force measurement.
    Example one: Universal S Type Load Cell FS4A-20kg with 2.0mV/V sensitivity powered by 5V DC, the output range is -10mV...+10mV.
    Example two: M6 Threaded S-beam Load Cell FS4A-2kg with 2.0mV/V rated output powered by 10V DC, the output range is -20mV...+20mV.
    The mV/V output from the wheatstone bridge sometimes can hardly be processed directly, a signal conditioner can be used with the load cell to deliver -5~5V, 0-10V or 4-20mA output.
    Example one: S-type Tension Compression Load Cell FS4A-5kg working with amplifier FSC(-5-5V)-24V, the Load-Voltage relationship will be 0-5kg compression force VS 0-5V output, 0-5kg traction force VS 0-(-5V), which is linear regardless of the measurement error, 1V output corresponds to 1kg compressive load, (-2V) output corresponds to 2kg tensile load, and so on.
    Example two: S-beam Tension Compression Sensor FS4A-10kg working with amplifier FSC(4-12-20mA)-24V, the Force-Current relationship will be 0-10kg compressive force VS 12-20mA output, 0-10kg tensile force VS 12-4mA, which is linear regardless of the measurement error, 12mA output corresponds to “0” load, 12.8mA output corresponds to 1kg compression load, 8mA output corresponds to 5kg tension load, and so on.

    s-type_load_cell_with_display_unit

    Dimensions

    5kg s type load cell 10kg

    Ordering codeMeasurement RangeForce direction
    FS4A-2kg0-20N / 0-2kgf

    Traction

    and

    Compression

    FS4A-5kg0-50N / 0-5kgf
    FS4A-10kg0-100N / 0-10kgf
    FS4A-20kg0-200N / 0-20kgf
    FS4A-30kg0-300N / 0-30kgf
    FS4A-50kg0-500N / 0-50kgf

    Click here to download datasheet

    Quality M6 Threaded S Beam Load Cell 2kg 5kg 10kg 20kg 30kg 50kg S-type Load Cell for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Forsentek Co., Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)