Sign In | Join Free | My burrillandco.com
Home > Compression load cell >

Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N

    Buy cheap Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N from wholesalers
     
    Buy cheap Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N from wholesalers
    • Buy cheap Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N from wholesalers
    • Buy cheap Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N from wholesalers
    • Buy cheap Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N from wholesalers
    • Buy cheap Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N from wholesalers

    Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N

    Ask Lasest Price
    Brand Name : Forsentek
    Model Number : FCCF
    Payment Terms : T/T,Western Union or Paypal
    Supply Ability : 2940pcs/month
    Delivery Time : 3~25 working days
    • Product Details
    • Company Profile

    Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N

    Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N

    Micro Clamping Force Load Cell FCCF is made of stainless steel based on strain gauge technology offering 50N / 100N / 200N / 500N four rated capacities intended for compression force measurement. Compact design with a mounting base makes it easy to install the transducer, 1000ohms high resistance minimizes the heat emission and improves long term stability. Miniature size enables button load cell FCCF applicable for appliations where mounting space is limited. You may find Miniature Compression Force Sensor FCCF suitable for applications such as load distribution analysis, mold pressure measurement, force overload protection, clamping force measurement, assembly force monitoring and so on.

    50N_Compression_Force_Measurement_100N

    A Load Cell is a transducer that converts force acting on it into electronic signal which is proportional to the applied force.The acting force causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply,the output signal between Sig+ and Sig- will change proportionally,thus the force can be measured by measuring the output signal from the load cell. Load Button Load Cell FCCF is designed to measure force in compression direction,outputs millivolt signal within 0~22.5mV, and signal amplification may be required for most applications, a load cell signal conditioner can be used to convert mV signal into -5-5V, 0-10V or 4-20mA output which is proportional to applied force.The amplified output then can be easily processed by PLCs and data acquisition software.

    Dimensions

    Miniature_Load_Button_Load_Cell100N_Compression_Force_Measurement_200N

    Ordering codeMeasurement RangeForce direction
    FCCF-50N0-11lbf / 0-5kgfCompression
    FCCF-100N0-22lbf / 0-10kgf
    FCCF-200N0-45lbs / 0-20kgf
    FCCF-500N0-112lbf / 0-50kgf

    Specifications

    Capacity

    50N / 100N / 200N / 500N

    5kgf / 10kgf / 20kgf / 50kgf

    11lb / 22lbs / 45lbf / 112lb

    Rated output1.5mV/V
    Excitation3-12V
    Zero balance±0.1mV/V
    Nonlinearity±1% of full capacity
    Hysteresis±1% of full capacity
    Nonrepeatability±0.5% of full capacity
    Creep(3min)±0.3% of full capacity
    Safe overload150% of full capacity
    Ultimate overload200% of full capacity
    Compensated temperature-10...+40oC
    Operating temperature-20...+60oC
    Temperature shift zero±0.05% R.O./oC
    Temperature shift span±0.05% R.O./oC
    Input resistance1000±100 ohms
    Output resistance1000±100 ohms
    Insulation resistance>5000M ohms
    Ingress protectionIP65
    Material of elementStainless steel
    CableØ1.9*3000mm 4-core shielded cable
    Wiring code

    Red--Excitation+ Black--Excitation-

    Green--Signal+ White--Signal-


    Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N

    200N_Compression_Force_Measurement_500N

    Output signal of load cell and amplifier:
    Load cell output: = (Power supply * Rated output) * Load / Capacity
    Rated output of Button Load Cell FCCF is normally around 1.5mV/V.
    Power supply of Miniature Load cell FCCF is normally within 3-15V.
    Load / Capacity is within 0-1.
    So the output range of Compression Type Force Sensor FCCF is normally within 0…+22.5mV.
    Example: Micro Compression Load Cell FCCF-50N with 1.5mV/V sensitivity powered by 10V DC,the output range is 0mV...+15mV.

    The mV/V output from the wheatstone bridge sometimes can hardly be processed directly, a signal conditioner can be used with the load cell to deliver -5~5V, 0-10V or 4-20mA output.
    Example: Mini Button Type Compression Load Cell FCCF-100N working with amplifier FSC(0-10V)-24V,the Load-Voltage relationship will be 0-100N compression force VS 0-10V output, which is linear regardless of the measurement error, 1V output corresponds to 10N compression load, 2V output corresponds to 20N compressive force, and so on.

    Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N

    500N_Compression_Force_Measurement_50N

    Click here to download datasheet

    Quality Compression Force Measurement 500N 200N Micro Button Load Cell 100N 50N for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Forsentek Co., Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)